Libros con envío GRATIS* a Península  Ver más

menú

0
  • argentina
  • chile
  • colombia
  • españa
  • méxico
  • perú
  • estados unidos
  • internacional
portada High-Repeatability Data Acquisition Systems for Pulsed Power Converters (en Inglés)
Formato
Libro Físico
Editorial
Idioma
Inglés
N° páginas
121
Encuadernación
Tapa Blanda
Dimensiones
22.9 x 15.2 x 0.8 cm
Peso
0.20 kg.
ISBN13
9781946646224

High-Repeatability Data Acquisition Systems for Pulsed Power Converters (en Inglés)

Pasquale Arpaia (Autor) · Carlo Baccigalupi (Autor) · Miguel Cerqueira Bastos (Autor) · Momentum Press · Tapa Blanda

High-Repeatability Data Acquisition Systems for Pulsed Power Converters (en Inglés) - Arpaia, Pasquale ; Baccigalupi, Carlo ; Bastos, Miguel Cerqueira

Libro Nuevo

45,46 €

50,51 €

Ahorras: 5,05 €

10% descuento
  • Estado: Nuevo
  • Quedan 100+ unidades
Origen: Estados Unidos (Costos de importación incluídos en el precio)
Se enviará desde nuestra bodega entre el Martes 23 de Julio y el Martes 06 de Agosto.
Lo recibirás en cualquier lugar de España entre 1 y 5 días hábiles luego del envío.

Reseña del libro "High-Repeatability Data Acquisition Systems for Pulsed Power Converters (en Inglés)"

This book addresses several issues related to the metrological characterization of high-performance pulsed power converters. Initially, a background and state-of-the-art on measurement systems for high-performance power converter are presented. In industrial applications of power converters metrology, specifications are often given in terms of worst-case uncertainty (WCU). Therefore, an analytical model for predicting the WCU of a measurement system is discussed and detailed for instruments affected by Gaussian noise. The authors discuss the study and design of a reference acquisition system for characterizing high-power pulses as well as the design of an on-line acquisition system for controlling the power converter. The book continues with numerical results obtained in simulation for the three main topics, which demonstrate the effectiveness of the proposals. Finally, the experimental results of a case study, carried out in the framework of the Compact Linear Collider (CLIC) at CERN, are reported. To meet CLIC requirements the two systems were designed to be ultra-low noise and are demonstrated to be repeatable in the order of few tens of parts per million (ppm).

Opiniones del libro

Ver más opiniones de clientes
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)
  • 0% (0)

Preguntas frecuentes sobre el libro

Todos los libros de nuestro catálogo son Originales.
El libro está escrito en Inglés.
La encuadernación de esta edición es Tapa Blanda.

Preguntas y respuestas sobre el libro

¿Tienes una pregunta sobre el libro? Inicia sesión para poder agregar tu propia pregunta.

Opiniones sobre Buscalibre

Ver más opiniones de clientes